Most emergency heating and cooling calls could have been avoided with regular preventative maintenance. All manufacturers recommend your heating and cooling systems to be serviced every year by a qualified technician. Our Preventative Maintenance Program will prolong the life of your system, greatly improve its efficiency and reduce your heating and cooling costs.
In order to not fall victim to avoidable breakdowns, we are encouraging all our customers to sign up for our yearly service program. Once you have committed to the program, we will schedule a qualified technician to inspect and service your equipment.
Unlike other maintenance programs there is no contract to sign - all additional repairs are approved by you first – and you can cancel the program at any time without any penalties. This program will automatically continue from year to year. We will contact you when your maintenance is due and schedule your appointment. For detailed list of what is inspected, see the attached listings.
Our complete Preventative Maintenance Flat rates are as follows:
| Equipment Type |
PMP Price ($) |
Geothermal |
$150.00 |
Gas Furnace / Boiler |
$120.00 |
Air Conditioner |
$110.00 |
Furnace / AC Combo |
$160.00 |
Fireplace |
$80.00 |
Radiant (non glycol systems) |
$80.00 |
Radiant ( with glycol) |
$120.00 |
HRV |
$80.00 |
Humidifier (only available with Furnace or A/C ) |
$35.00 |
|
*Note if glycol is required it will be charged extra*
Geothermal
PMP Check List
- Check Thermostat
- Lubricate fan motor & pump
- Test blower operations
- Check safety controls
- Inspect air control
- Check for signs of leakage
- Check circulator for operation
- Test for lubrication
- Check air rise
- Vacuum blower assembly
- Vacuum electronics
- Inspect air filter
- Check pump down
- Check line voltage
- Check water – loop in/out
- Test water flow
- Test heat & cool cycle
- Test desuperheater pump
- Test refrigeration level (if needed)
- Test loop pressure & adjust (if required)
- Inspect coaxial heat exchanger
|
Gas Furnace / Boiler
PMP Check List
- Check thermostat
- Lubricate fan motor, bearings & pump
- Inspect gas piping
- Check belt tension & condition
- Test blower operation
- Check furnace safety controls
- Inspect heat exchanger
- Check pilot safety operation
- Check heat rise
- Check CO (record)
- Check venting system and controls
- Clean & calibrate burners
- Check electronic ignition system
- Clean pilot burner
- Inspect secondary heat exchanger
- Check gas pressure (clock meter & record)
- Check combustion ventilation air
|
Fireplace
PMP Check List
- Check thermostat
- Lubricate fan motor, bearings, & pump
- Inspect gas piping
- Check belt tension & condition
- Test blower operation
- Check furnace safety controls
- Check venting system & controls
- Inspect heat exchanger
- Check pilot safety operation
- Check heat rise
- Check CO (record)
- Clean & calibrate burners
- Check electronic ignition system
- Clean pilot burner
- Inspect secondary heat exchanger
- Check gas pressure ( clock meter & record)
- Check combustion ventilation air
- Vacuum log set
- Clean glass
|
Air Conditioner
PMP Check List
- Check thermostat
- Inspect fan belt
- Test blower operation
- Inspect filter system
- Adjust humidifier damper position
- Check drain condition
- Check condensate pump operation
- Inspect evaporator coil
- Check contactor
- Check compressor operation
- Inspect condenser coil
- Check & record refrigerant level
- Lubricate fan & motor
- Clean drain line
- Tighten electrical connections
- Inspect condenser fan blades
- Check capacitor
- Clean condenser coil
- Clean condenser housing
- Check & record electrical loads
|
Heat Recovery Ventilator
PMP Check List
- Clean filter
- Check wire connections
- Clean & check core
- Check & oil fan motor
- Clean & check condensate drain line
- Clean outdoor vents
|
Humidifier
PMP Check List
- Check drum & pad
- Check float operation
- Check solenoid operation
- Test run unit
- Check low voltage connections
- Clean drain
- Check air leak
- Check for water leaks
- Check humidistat
|
Radiant
PMP Check List
- Check system operating pressure
- Perform visual leak test
- Test electrical operation of each controller
- Test glycol ( if applicable)
- Top up glycol if required
- Check thermostat
- Check temperature of incoming and outgoing water
- Check operation of circulating pumps
|
| |
| |
|